DAY 1: WELCOME, INTRODUCTION, LEVEL 1 & 2 |
Duration |
Topic |
9.00am – 10.00am
(1 hour) |
1. Welcome & Introduction to Mechanical Services
- Get to know each other
- What we will cover and a few insights into the content
|
10 mins |
Break |
10.10 - 11.10am
(1 hour) |
2. Level 1 -Statutory
- Council requirements
- Building regulations
- Australian Standards
- Safety
- Other
- Typical development compliance framework and exclusions
- Complying development and development applications
- Interface with certifying authority
|
15 mins |
Break |
11.25am – 12.25pm
(1 hour) |
3. Level 1 – Cost
- Capital investment
- Asset positioning
- Operation costs
- Lifecycle costing
- Other
- Project funding, who pays to build, own, operate and maintain?
- How is the asset valued?
- What are the current and future impacts on asset value?
|
35 mins |
Lunch break |
1.00pm – 2.00pm
( 1 hour) |
4. Level 1 - Technical
- Project objectives and requirements
- Comfort criteria, air movement, temp, humidity, radiation, olfactory, noise, glare
- Building modelling and passive elements
- Embodied energy (sustainability concept / circular economy etc))
- History and principles of heating, ventilation and air conditioning technology
- Impact of HFC's and HCFC's on the environment
- Impact of operational carbon emissions on the environment
- How to calculate emissions over equipment lifecycle
- Systems engineering and system selection
- Space requirements for mechanical systems
- Materials and reticulation systems
- Control, monitoring and reporting
|
10 mins |
Break |
2.10pm – 3.10pm
(1 hour) |
5. Level 1 - Technical
- How are the project and comfort criteria determined?
- Indoor Air Quality & Ventilation
- Principles of passive design elements
- Heating and cooling load estimation
- Calculating operational emissions
|
15 mins |
Break |
3.25pm – 4.25pm
(1 hour) |
6. Level 2 – Cost and Statutory
- How the regulatory hierarchy works
- How standards and referenced
- How safety is managed
- How capital costs are estimated
- How operation costs are estimated
- Value of sustainability criteria
- Trends for carbon accounting and net-zero
|
4.25pm – 5.00pm
(35 minutes) |
Q&A and Close |
DAY 2: MECHANICAL SERVICES LEVEL 2 |
Duration |
Topic |
9.00am – 9.15am
(15 minutes) |
Check in / Re-cap Day 1 / Agenda Day 2 |
9.15am – 10.30am
(1 hour 15 minutes) |
7. Level 2 – Statutory and Technical
- Common HVAC system types in Australia
- Space requirements of different HVAC systems
- Reticulation space requirements for different HVAC systems
- Sick Building Syndrome
|
15 mins |
Break |
10.45am – 12.30pm
(1 hour 45 minutes) |
8. Level 2 – Technical continued
(see above) |
45 mins |
Lunch break |
1.15pm – 3.00pm
(1 hour 45 minutes) |
9. Level 2 – Technical continued
(see above) |
15 mins |
Break |
3.15pm – 4.30pm
(1 hour 15 minutes) |
10. Level 2 – Technical continued
(see above) |
4.30pm – 5.00pm
(30 minutes) |
Q&A and Close |
DAY 3: MECHANICAL SERVICES LEVEL 3 |
Duration |
Topic |
9.00am – 9.15am
(15 minutes) |
Check in / Re-cap Day 1&2 / Agenda Day 3 |
9.15am – 10.30am
(1 hour) |
11. Level 3 - Cost and Statutory
- Specific standards most relevant to HVAC design in Australia
- Performance solutions and deemed to satisfy (DTS) compliance
- Industry and project specific standards (health, defence, other)
- History and principles of fire compartmentation & control systems
- Statutory requirements of energy efficiency of buildings
- How to compute future expenses into current value (nett present value calculation)
- Why lifecycle costs are important
- Limitations of estimates
Discretionary environmental standards, governance, objectives and compliance |
15 mins |
Break |
10.45am – 12.30am
(1 hour 45 minutes) |
12. Level 3 - Technical
- Equipment and systems specific introduction
- How DX and VRF systems work and how to size them
- How exhaust ventilation systems work and how to design them
- How chillers work and how to select them
- How boilers work and how to select them
- How pumps work and how to select them
- Fans and Air Distribution
- How FCU's and AHU's work and how to design them
- VAV / CAV
- How chilled beams work and how to design them
- How heat pump heating works and how to design it
- Hydronic circuit design and control
- Buffer tank design and control
- Evaporative cooling (direct and indirect)
- Healthcare
- Controls
- Commissioning
- Maintenance
Noise and vibration design |
45 mins |
Lunch break |
1.15pm – 3.00pm
(1 hour 45 minutes) |
13. Level 3 – Technical continued
(see above) |
15 mins |
Break |
3.15pm – 4.30pm
(1 hour 15 minutes) |
14. Level 3 – Technical continued
(see above) |
4.30pm – 5.00pm
(30 minutes) |
Q&A and Close |
DAY 4: MECHANICAL SERVICES LEVEL 3 AND CLOSE |
Duration |
Topic |
9.00am – 9.15am
(15 minutes) |
Check in / Re-cap Day 1, 2 &3 / Agenda Day 4 |
9.15am – 10.30am
(1 hour) |
11. Level 3 – Technical continued
(see above) |
15 mins |
Break |
10.45am – 12.30am
(1 hour 45 minutes) |
12. Level 3 - Technical continued
(see above) |
45 mins |
Lunch break |
1.15pm – 3.00pm
(1 hour 45 minutes) |
13. Level 3 – Technical
(see above) |
15 mins |
Break |
3.15pm – 4.15pm
(1 hour) |
14. Wrap Up - Level 1, 2 & 3 |
4.15pm – 4.45pm
(30 minutes) |
Q&A, Close & Farewell |