Module 1
Is a 90M Fire Damper CPD technical training presentation (covering FD & MFD) which explains and encourages conversations on topics including -
• Fire Damper standards
• Fire Damper classifications
• What is the difference between an MFSD, FD, MFD or SCD
• Fire Damper compliance - how to read a DoP
• How to make a correct damper selection
• Breakaway connections
• What is a non-standard damper application?
• Why do you need an insulated damper?
• What is an EXAP?
• Can a 120M (FD or MFD) damper be installed in a 30M wall?
• What are standard constructions and what are non-standard
Constructions?
• Why are there challenges around MMC and standard fire testing
• What is the minimum damper spacing
• MFD & FD Installation & good practices
Module 2
Is a 60M Smoke Control damper technical training presentation (covering SCD’s), which builds directly on the knowledge gained in module 1 and explains and encourages dialogue on topics such as -
• Smoke Control Damper standards
• Smoke Control Damper classifications
• Smoke Control Damper compliance - how to read a DoP
• How to select the correct SCD
• Does the Duct and Damper need to be tested together?
• Why you need an insulated SCD
• Do interfaces need to be tested with the damper?
• What are standard constructions and what are non-
Standard constructions
• Do I need a single or multi compartment damper?
• Do I need AA or MA operation
• Can an MFD be used in a SCD system?
• Does BS 8519 affect damper selection?
• What should be included in a SCD test and detailed on a DoP
• SCD Installation & good practices
Module 3
Is a 60M Smoke Damper Control system technical CPD presentation (for MFD & SCD) on regulations, this builds directly on the knowledge gained in module's 1 and 2 and encourages conversations in an overlooked area of compliance with topics such as -
• How does the Silo approach affect compliance?
• Control System compliance BS ISO 21927-9 and
System requirements
• Can you control an MFD and/or SCD system from a
Fire alarm system?
• What does AA or MA mean in damper control system?
• C&E design and responsibility
• Hardwired versus Loop systems
• 24V versus 230V systems
• Do interfaces and ancillaries need to be fire tested?
• Is a firefighter's override required?
• Cable specifications to BS 8519
• Commissioning a damper control system
- Fire
Fire
Martin Fackrell is a fire safety industry veteran and the founder of Mandik UK Limited. Beginning his career as an apprentice at Airstream Ltd, he rose through the ranks to hold senior national sales and technical management positions at Aumüller, SE Controls, and Swegon. In 2020, he established Mandik UK to provide a fresh, integrity-driven approach to fire and smoke control dampers. Today, Martin leads a team of 17 and serves on the technical committees for BESA and the ASFP, driving the highest standards of damper and controls compliance across the UK fire safety market.
3
Seminars or Webinars;Online and Video Learning;On Site at Provider’s Location;Workshops;Presentations;Questions and Answers
1 hr;2 hrs;3 hrs;Half Day
Free of Charge
04/04/2024
31/03/2026
- East Anglia England
- East Midlands England
- Europe
- Ireland
- London
- North East England
- North West England
- Northern England
- Northern Ireland
- Scotland
- South East England
- South West England
- Southern England
- Wales
- West Midlands England